Precision Flexible AC Current Probe based on Rogowski principle for current, power, energy and electricity quality applications
• Accuracy up to 0.2 % in amplitude and 0.1° in phase
• No additional error for wire position
• Symmetric flexible shielding pp for excellent suppression of strange electric fields
• Symmetric sensor coil pp for excellent suppression of strange magnetic fields
• Low noise, dual gain, high CMRR amplifier with precision integrator pp
• Low output impedance
• Two sensor cable models: high voltage Ø 12.6 mm and super flexible Ø 6 mm
• Low cost models with software calibration in serial EEPROM available in single or
three phase version
• Extremely long sensor cable pp for large structures like buildings, towers, masts etc.
• Application tailored pp sensor cable sensitivity and frequency range
• High frequency matched pp sensor coil for broad frequency band and surge current measurements
• Calibration kit available
| Amplitude / Phase Accuracy |
Hardware calibration |
Software calibration |
| Single phase |
Single phase |
Three phase |
| 0.5 % / 0.3° |
FCP 2110D |
FCP 3110D |
FCP 3310D |
| 0.2 % / 0.1° |
FCP 2110C |
FCP 3110C |
FCP 3310C |
|
| General Specifications |
|
| Basic Frequency |
40 Hz .. 5 kHz |
| Working Frequency (3dB) * |
0.8 Hz .. 50 kHz |
| Gain * |
100 mV/A & 1 mV/A |
| Measuring Range (crest factor <1.5) |
30 mA - 3 000 A |
| Output Voltage Maximum |
± 4.5 V peak |
|
|